MAGNETIC FLOW METER

ELECTROMAGNETIC FLOW METER

A range of high-quality, economically priced magnetic flow meters for water and wastewater flow.

Magnetic Flow Meters (Magmeters) are designed to measure the flow of electrically conductive liquids in a closed pipe. Magmeters are volumetric flow measuring devices and are very well known for their high accuracy and repeatability. The most common type of Magnetic Flowmeter is normally a flanged flow sensor wedged in between flanges. The only wetted parts are the flow electrodes and liner which can protect the sensor from corrosive chemicals.

Magnetic flowmeters can also be offered with sanitary connections for food applications such as milk and dairy products. The output flow signal is directly proportional to the flow velocity.

We provide the magnetic flow meter and a calibration certificate from an ILAC certified calibration house. A Magnetic Flow Meter measures volumetric flow rate and is popular where very low maintenance is required. Operators can simply order a magnetic flow meter, install it and forget about it.

How Magnetic Flow Meters work?

 Faraday’s Law, is mathematically defined as,

E=K*B*D*V.*T.

The *Induced voltage is directly proportional to the velocity of the fluid moving through the magnetic field. This induced voltage is literally carried to the transmitter through the electrode circuit. *Induced voltage is produced as a result of electromagnetic induction.

There are two major components of a Magnetic Flowmeter. The Magmeter is a signal converter with basic components like magnet coils and electronics and traditional design is a body made up of a flange section and pipe. However, alternative Magnetic Flowmeter styles are wafer and insert Magnetic flow probe. 

Magnetic Flow Meter Advantages
  • Obstructionless Design
  • Linear Output
  • Corrosion resistant wetted parts
  • High Accuracy

Magmeter Features

  • Water abstraction flow
  • Water purification and desalination flow
  • Drinking water distribution networks 
  • Revenue metering or billing
  • Leakage detection
  • Irrigation flow
  • Industry water
  • Cooling water flow rate
  • Wastewater flow
  • Sewage and sludge flow
  • Sea water flow

Specification

Dimension

Millimeter

Pressure (Bar)

Insertion Length (mm)

Thread

Flange

100 to 200

16

400

480

250 to 400

16

500

580

450 to 1200

16

600

680

1400 to 2000

16

800

880

 

External Dimension (mm)

Reference Weight

Nominal

PTFE/PFA

Neoprene

L

H

Kilogram

3

200 (PFA)

90

220

4

6

90

220

5

10

200

90

220

6

15

200

95

220

8

20

200

100

220

10

25

200

115

223

12

32

200

140

240

13

40

200

200

150

250

14

50

200

200

165

263

15

65

250

250

185

283

18

80

250

250

200

290

20

100

250

250

235

318

25

125

250

250

270

350

28

150

300

300

300

380

30

200

350

350

300

430

50

250

450

450

405

495

70

300

500

500

460

547

95

350

550

550

520

602

120

400

600

600

580

665

140

450

600

600

640

720

160

500

600

600

715

783

200

600

600

600

840

897

280

700

700

700

895

982

350

800

800

800

1015

1092

400

900

900

900

1115

1192

480

1000

1000

1000

1230

1299

550

1200

1200

1200

1405

1488

660

1400

1400

1400

1630

1700

750

1600

1600

1600

1830

1924

850

1800

1800

1800

2045

2134

980

2000

2000

2000

2265

2344

1200