ELECTROMAGNETIC FLOW METER
A range of high-quality, economically priced magnetic flow meters for water and wastewater flow.
Magnetic Flow Meters (Magmeters) are designed to measure the flow of electrically conductive liquids in a closed pipe. Magmeters are volumetric flow measuring devices and are very well known for their high accuracy and repeatability. The most common type of Magnetic Flowmeter is normally a flanged flow sensor wedged in between flanges. The only wetted parts are the flow electrodes and liner which can protect the sensor from corrosive chemicals.
Magnetic flowmeters can also be offered with sanitary connections for food applications such as milk and dairy products. The output flow signal is directly proportional to the flow velocity.
We provide the magnetic flow meter and a calibration certificate from an ILAC certified calibration house. A Magnetic Flow Meter measures volumetric flow rate and is popular where very low maintenance is required. Operators can simply order a magnetic flow meter, install it and forget about it.
How Magnetic Flow Meters work?
Faraday’s Law, is mathematically defined as,
E=K*B*D*V.*T.
The *Induced voltage is directly proportional to the velocity of the fluid moving through the magnetic field. This induced voltage is literally carried to the transmitter through the electrode circuit. *Induced voltage is produced as a result of electromagnetic induction.
There are two major components of a Magnetic Flowmeter. The Magmeter is a signal converter with basic components like magnet coils and electronics and traditional design is a body made up of a flange section and pipe. However, alternative Magnetic Flowmeter styles are wafer and insert Magnetic flow probe.
Magnetic Flow Meter Advantages
- Obstructionless Design
- Linear Output
- Corrosion resistant wetted parts
- High Accuracy
Magmeter Features
- Water abstraction flow
- Water purification and desalination flow
- Drinking water distribution networks
- Revenue metering or billing
- Leakage detection
- Irrigation flow
- Industry water
- Cooling water flow rate
- Wastewater flow
- Sewage and sludge flow
- Sea water flow
Specification
Dimension
Millimeter | Pressure (Bar) | Insertion Length (mm) | |
Thread | Flange | ||
100 to 200 | 16 | 400 | 480 |
250 to 400 | 16 | 500 | 580 |
450 to 1200 | 16 | 600 | 680 |
1400 to 2000 | 16 | 800 | 880 |
| External Dimension (mm) | Reference Weight | |||
Nominal | PTFE/PFA | Neoprene | L | H | Kilogram |
3 | 200 (PFA) | 90 | 220 | 4 | |
6 | 90 | 220 | 5 | ||
10 | 200 | – | 90 | 220 | 6 |
15 | 200 | – | 95 | 220 | 8 |
20 | 200 | – | 100 | 220 | 10 |
25 | 200 | – | 115 | 223 | 12 |
32 | 200 | – | 140 | 240 | 13 |
40 | 200 | 200 | 150 | 250 | 14 |
50 | 200 | 200 | 165 | 263 | 15 |
65 | 250 | 250 | 185 | 283 | 18 |
80 | 250 | 250 | 200 | 290 | 20 |
100 | 250 | 250 | 235 | 318 | 25 |
125 | 250 | 250 | 270 | 350 | 28 |
150 | 300 | 300 | 300 | 380 | 30 |
200 | 350 | 350 | 300 | 430 | 50 |
250 | 450 | 450 | 405 | 495 | 70 |
300 | 500 | 500 | 460 | 547 | 95 |
350 | 550 | 550 | 520 | 602 | 120 |
400 | 600 | 600 | 580 | 665 | 140 |
450 | 600 | 600 | 640 | 720 | 160 |
500 | 600 | 600 | 715 | 783 | 200 |
600 | 600 | 600 | 840 | 897 | 280 |
700 | 700 | 700 | 895 | 982 | 350 |
800 | 800 | 800 | 1015 | 1092 | 400 |
900 | 900 | 900 | 1115 | 1192 | 480 |
1000 | 1000 | 1000 | 1230 | 1299 | 550 |
1200 | 1200 | 1200 | 1405 | 1488 | 660 |
1400 | 1400 | 1400 | 1630 | 1700 | 750 |
1600 | 1600 | 1600 | 1830 | 1924 | 850 |
1800 | 1800 | 1800 | 2045 | 2134 | 980 |
2000 | 2000 | 2000 | 2265 | 2344 | 1200 |